Fingertip Pulse Oximeter 

Payment Terms: T/T,WU;Paypal 
Place of Origin: Hebei, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: CMS50D1
Delivery Date: delivery in five days
Packing: CARTON

TheFingertip PulseOximeter CMS50D1

TheFingertip PulseOximeter CMS50D1


Principle of the CMS50D1 Pulse Oximeter is as follows: Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning & Recording Technology,the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger.The product is suitable for being used in family, hospital, oxygen bar, community healthcare, physical care in sports (It can be used before or after doing sports, and it is not recommended to
use the device during the process of having sport) and etc.

Major Features

Integrated with SpO2 probe and processing display module
Small in volume\light in weight and convenient in carrying
Operation of the product is simple ,low power consumption
SpO2 value display
Pulse rate value display, bar graph display
Pulse waveform display
The display mode can be changed
Screen brightness can be changed
Low-voltage indication: low-voltage indicator appears before working abnormally  which is due to low-voltage
Automatically power off function: when the device is under the state of measuring interface . it will automatically
power off within 5 seconds if the finger falls out of probe
Display format can be saved after power off
Main performance

Display Mode: 0.96" Dual-color OLED display(blue and yellow)
Screen Resolution: 128*64
SpO2 Measuring Range: 0%~100%, (the resolution is 1%).
Accuracy: 70%~100%: ±2% ,Below 70% unspecified.
PR Measuring Range: 30bpm~250bpm, (the resolution is 1bpm)
Accuracy: ±2bpm or ±2% (select larger)
Measurement Performance in Weak Filling Condition:
SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%,
pulse rate error is ±2 bpm or ±2% (select larger).
Resistance to surrounding light: The deviation between the value measured in the condition of man-made
light or indoor natural light and that of darkroom is less than ±1%.
Power Consumption: less than 30mA
Voltage: DC 3.0V
Power Supply:1.5V (AAA size) alkaline batteries × 2  
Battery working hour: Theoretical number is 32 hours.
Safety Type:Interior Battery, BF Type
Accessories

Sell in standard:

A hanging rope
A user manual
Physical Identity

Dimension: 61(L) × 36(W) × 32(H) mm
Weight: About 60g (with the batteries)
available for home blood-oxygen monitoring.

bigPhoto
 Mr. Blair
sales manager
Tel: 86-335-7788304
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

Contec Medical Syatems CO,.LTD [China (Mainland)]


Business Type:Manufacturer, Trading Company, Distributor/Wholesaler
City: Qinhuangdao
Province/State: Hebei
Country/Region: China (Mainland)

You May Like:

Product (27)